Fire-Lite LTE and 5G ready fire alarm communicators represent a leading-edge Internet and/or LTE cellular communications solution for monitoring fire alarm systems. Our fast, secure, and effective alarm communications technology enables connection to any Contact-ID fire alarm control panel (FACP).
Communicators
Fire-Lite 411UDAC Fire-Watch Stand-alone Slave Fire Alarm Communicator, Dual-Line, Four-Channel, Red Cabinet
The Fire-Watch 411UDAC from Fire-Lite Alarms is a stand-alone slave Fire Alarm Communicator designed for a variety of fire and non-fire applications. It provides four channels (inputs) that accept normally open devices including waterflow devices, detectors and pull stations. This dialer is a cost-effective solution for applications that require a Fire alarm control panel to transmit system status to an off-site central station monitoring facility.

Features & Benefits:
- Flexible and configurable to meet your communication and central station requirements.
- Four supervised monitoring channels (inputs):
- Three fixed Style B (Class B) and one Style A (Class A) or Style B (Class B).
- Two new onboard relays are now included on the main circuit board.
- One Style Y (Class B) Notification Appliance (bell) Circuit (NAC).
- 1.0 Amp notification appliance power.
- Large cabinet with increased knockouts and space to house a large battery.
- Includes 15 popular communication formats, including the widely used Ademco Contact ID format, ensuring compatibility with virtually all DACRs.
- Industry-first, UL recognized, “dialer runaway” prevention feature.
Honeywell HWF2V-COM Fire Alarm Communicator, for Verizon LTE/LP Network (Replaces IGSMCFP4G & IPGSM-4G)
Honeywell’s HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer contact ID reporting with any fire alarm control panel (FACP) with a built in dialer. These easy to install communicators offer three selectable reporting paths which include LTE Cellular only, IP only, or IP primary/LTE cellular backup.

- ReplacesIPGSM-4G &IGSMCFP4G
- AT&T (HWF2A-COM) and Verizon Wireless (HWF2V-COM) models available
- Dual path communications to central station using Internet or LTE cellular technology
- Requires no change to the existing Fire Alarm Control Panel configuration with connection to primary and secondary telephone ports
- Works on Ethernet 10/100 ports
- Base network connection (LAN or WAN), DSL or cable modem
- Eliminates the cost of two dedicated phone lines
- Data transmits over standard contact-ID protocol but is secured with the industry’s advanced encryption standard (AES 256 bit)
- Includes primary power and battery supervision
- Built-In Power Supply module: On board charging circuit design accommodates back-up battery
- Diagnostic LEDs: Signal strength and status indicators to simplify troubleshooting
alula BAT-FIRE-VZ Universal 5G-Ready Fire Communicator, Verizon
The BAT-Fire Commercial FACP Communicator is the ideal solution for system integrators who want a versatile fire communicator. Equipped with dual path IP and LTE-M cellular technology and four programmable input/outputs, system integrators can save money, maximize install flexibility, and skip the 4G sunset.

General Information
DSC LE4010CF-AT LTE Universal Wireless Commercial Fire Alarm Communicator AT&T
Due to rapidly-evolving cellular technologies, 2G/3G network sunsets are already on the horizon – with some having already been completed. Now’s the time to adopt and adapt. Switch to LTE today, to offer customers long-lasting investment protection, and reduce your future truck rolls.
The LE4010CF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System I-IP/II/III/IV/5). The LE4010CF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format.
The LE4010CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013/2016) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure.

Features & Benefits:
-
UL Listing
The LE4010CF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE4010CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE4010CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE4010CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station.
General InformationName: DSC LE4010CF-AT LTE Universal Wireless Commercial Fire Alarm Communicator AT&T, Tyco International, Ltd, DSCCategory: DSC, Fire, Fire Control Panels, Alarm CommunicatorsUPC Code: 80007749Country of Origin: Mexico. Country of origin is subject to change.
Silent Knight 5104B Six-Zone Fire Alarm Communicator, 12 VDC, UL Listed
The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It’s UL 864 and NFPA 72 approved for monitoring local evacuation controls.
As a stand-alone unit, it can be used to monitor:
- Sprinkler systems for water flow, supervisory, and gate valve tamper conditions.
- Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours).
- Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each.
The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition tothe central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure.
The communicator will signal activation, restoration and trouble conditions on any of the six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications.

Features & Benefits:
- UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit.
- Can be used as a stand-alone or as an add-on DACT.
- FM approved.
- Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs.
- Downloadable for remote programming.
- Fuseless overload protection with automatic reset circuitry and fault indicators — eliminates the cause of most field calls
- Dual phone line interface Automatic self tests every 24 hours with report sent to central station.
- Reports in SIA and most major communications formats.
- 60 hours of standby power.
- Operates on loop start phone lines ahead of the building PBX system.
- A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes).
Bosch D9068 Fire Dialer Digital Alarm Transmitter Communicator
The D9068 Fire Communicator is a complete digital alarm communicator transmitter (DACT) for use with compatible fire alarm control panels (FACPs). Use dry contacts or open collector outputs for alarms and communications with the D9068.
Functions | Five Input Points
The DACT supports five inputs that can be activated by dry contact relays or open collector outputs. Each of these inputs can be configured for one of seven types of conditions: Fire Alarm, Waterflow Alarm, Supervisory, Monitor Alarm, System Fault, AC Failure and Low Battery.
System Supervision
The DACT is supervised with a hardware watchdog circuit. Failure of the control program results in a hardware reset within two seconds. The on-board trouble relay releases for the duration of the reset (the relay is normally held energized).
The DACT’s EEPROM memory, input points, and phone lines are automatically tested periodically. The EEPROM checksum is verified every 10 minutes. If the EEPROM checksum fails, a trouble condition is locally annunciated and a trouble report sent.

Serial Data Input Dialing
The DACT connects through the D9052 Serial Module to the D10024, D10024A, D9024, and D8024 analog FACPs, and transmits by point in all available formats.
User Interface
An FMR-DACT-KEYPAD LCD Keypad connects to a five-pin connector (option bus interface) and is used to program and troubleshoot the D9068. A D7033 Liquid Crystal Display (LCD) Remote Keypad can also be used.
Reporting Formats
The DACT supports five reporting formats: Modem IIIa, Contact ID, SIA110, SIA300, and 4/2.
Report Routing
There are six different report groups that can be routed to one of four phone settings. These report groups consist of non-supervisory alarms, supervisory alarms, alarm restorals, resets, supervisory restorals, tests and troubles, and trouble restorals.
Reset Report
A reset report is sent when the D9068 resets from any off-normal condition.
Phone Line Selection
The DACT follows a pre-determined sequence to select between the phone lines. It also implements the new NFPA requirements for alternation of phone lines during test reporting. The DACT maintains a variable that selects either Phone Line 1 or Phone Line 2 for automatic test reports. After each successful test report, the variable switches to select the other phone line.
Communication Failed Indication
The DACT indicates a communication failure after ten attempts to communicate are completed without success. This causes the trouble output to activate and report the fault.
Honeywell HW-TG7LVF02 Telguard CLSS-Enabled LTE Commercial Fire Alarm Communicators for Verizon TG-7FS LTE-V
CLSS-Enabled LTE Commercial Fire Alarm Communicators for AT&T® and Verizon®
The dialer capture solution to connect commercial fire systems to central monitoring stations and the CLSS Cloud.
Enabled by cooperation between Telguard® and Honeywell®, the HW-TG7L Fire Series starts with Telguard’s model TG-7FS and adds the powerful capabilities of Honeywell’s Connected Life Safety Services (CLSS) Cloud.
The CLSS LTE Fire Communicator transmits alarm signals from the fire panel over the LTE networks of AT&T (HW-TG7LAF02) and Verizon (HW-TG7LVF02) to the designated monitoring station while leveraging connectivity with CLSS to enable powerful tools.
Compliant with 2019 and earlier editions of NFPA 72, the CLSS LTE Fire Communicator can serve as the sole communication path. For existing installations, all landlines dedicated to the master control unit can be replaced with a single CLSS LTE Fire Communicator because of its 5 or 60-minute supervision modes.

HONEYWELL CONNECTED LIFE SAFETY SERVICES (CLSS)
Honeywell CLSS is an innovative, all-in-one cloud platform that enables systems integrators and facilities managers to deliver an enhanced fire safety service, while maximizing the performance efficiencies offered by Honeywell’s trusted detection and alarm systems. The CLSS platform enables users to:
- Get a “bird’s eye” view of all accounts
- Obtain real-time information on event generation, enabling diagnosis before dispatch
- Conduct tests and inspections using a mobile app (available in select markets)
- Provide end users withmulti-site asset informationand event alerts
TELGUARD INTERNET PORTAL
Telguard makes adopting cellular easy with a secure internet portal that provides total account management of UL-listed Telguard cellular alarm communicators. Quickly access Telguard-based services 24/7.
TELGUARD CELLULAR SERVICE
Telguard Cellular Service provides AT&T and Verizon® LTE network coverage for all Telguard units. In Canada, cellular service may be provided by Rogers, Bell, TELUS, or SaskTel. Telguard’s Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products, and the central station. Telguard technical support provides a single point of contact for both cellular service and Telguard product questions.
Main Features
- Integration with CLSS enables monitoring of event transmission data & management of device inventory from the CLSS mobile app and web portal (available only when using Contact ID and point-based reporting)
- Alarm format support for contact ID, SIA2, pulse (3×1, 4×2), modem lle, IIIa, and DMP
- Certified for use on the AT&T and Verizon LTE networks
- Meets UL 864 requirements for sole primary or backup path communications
- Minimizes false alarms by providing dual paths for self-tests
- Falls back to 3G/4G if an LTE network is not available, for extended network coverage
- 60- or 5-minute cellular supervision available; 180-seconds available in Canada
- Telephone line monitor built-in, with standard line security
- Automatic self-test (daily or 6-hour)
- Available relay output for tripping the alarm control panel when a trouble condition occurs
- Locking, red metal enclosure
- Two programmable supervisory trip outputs
- Allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration
Fire-Lite ES-50X 50-Point Addressable Fire Alarm Control Panel
The Endurance Series ES-50X is a 50-point addressable fire alarm control panel that offers built-in dual path communications, programmable buttons and support for combined fire and CO addressable detection.

Features & Benefits:
- Upload/Download panel programming database and flash firmware with USB thumb drive
- Addressable multi-criteria detector (smoke, heat, CO) with programmable response
- Addressable Sounder Bases
- Four programmable function keys
- Built in Class-A capability for all 4 NACs; no optional card required
- Trouble indication for SLC devices not programmed
- Automatic discovery of “relay” versus “NAC” type control modules during auto-programming of SLC loop
- Integrated SWIFT display driver and annunciator built-in to panel
-
General InformationName: Fire-Lite ES-50X 50-Point Addressable Fire Alarm Control Panel, Honeywell International, Inc, Fire-Lite Alarms by HoneywellCategory: Fire-Lite Alarms by Honeywell, Fire, Fire Control Panels, Fire Alarm Control PanelsUPC Code: 783008112622Country of Origin: United States. Country of origin is subject to change.
Keeping You Informed
Alarmco Systems works with customers to keep them informed with new product solutions.
Process steps in our projects
Technology
Offer the best available products.
Design
System designs that are cost effective.
Development
Putting solutions in your business
Deployment
Monitoring 24/7/365