Fire-Lite offers a variety of annunciators that mimic the fire alarm control panel and provide system status indicators to support different installation requirements.
Annunciators
ANN-LED Annunciator Module
ANN-LED annunciator modules provide LED annunciation of general system faults and input zones/points when used with a compatible fire alarm control panel (FACP).
ANN-LED annunciator modules provide LED annunciation of general system faults and input zones/points when used with a compatible fire alarm control panel (FACP). These modules provide alarm (red), trouble (yellow), and supervisory (yellow) indication for up to 10 input zones or addressable points. Models available with red LEDs only for alarm communication of up to 30 addressable points.

Features & Benefits:
- ANN-LED connects to the ANN-Bus terminal on the FACP and requires minimal programming
- Includes three LEDs for each zone: Alarm, Trouble and Supervisory.
- Compatible with the ES-200X, ES-50X, MS-9600(UD)LS, MS9200UDLS, MS-9050UD, MS-5UD, MS-10UD, MRP-2001, and MRP-2002,
- Can be remotely located up to 6,000 feet (1,829 m) from the panel
- May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC)
Certifications:
Fire-Lite LCD-80F 80-Character Backlit LCD Remote Fire Annunciator for MS9200UD Series & MS-9600 Series
LCD-80F remote annunciators are compact, cost-effective LCD remote annunciators for use with Fire-Lite® fire alarm control panels (FACPs).
The LCD-80F is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the Fire•Lite MS9200UD Series and MS-9600 Series Fire Alarm Control Panels (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions. Up to 32 LCD-80Fs may be connected onto the EIA-485 terminal port of each FACP. The LCD-80F requires no programming, which saves time during system commissioning.

Main Features
- 80-character Liquid Crystal Display.
- Mimics all display information from the host panel.
- Control switches for System Acknowledge, Signal Silence,
- Drill and Reset with enable key.
- System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced.
- No programming necessary — LCD-80F connects to the
- terminal port (TB7) .
- Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels.
- Time-and-date display field.
- Aesthetically pleasing design.
- May be powered from the host FACP or by remote power supply (requires 24 VDC).
- Up to 32 LCD-80F annunciators per FACP.
- Plug-in terminal blocks for ease of installation and service.
- Can be remotely located up to 6,000 feet (1828.8 m) from
- the FACP.
- Local piezo sounder with alarm and trouble resound.
- Semi-flush mounts to 2.188″ (5.556 cm) minimum deep, three-gang electrical box (Fire-Lite PN 10103) or three-gangable electrical switchbox.
- Surface-mounts to Fire-Lite PN SBB-3 surface backbox.
N-ANN-100 Annunciator
The N-ANN-100 annunciators is a backlit, 80-character LCD fire annunciators that mimics the Fire Alarm Control Panel (FACP) display.
The N-ANN-100 annunciators is a backlit, 80-character LCD fire annunciators that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN-100 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply.

Features & Benefits:
- Features & Benefits:
- Backlit 80-character LCD display
- Mimics all display information from the host panel
- Control switches for Signal Silence, System Acknowledge, Reset, and Drill
- Control switches can be independently enabled or disabled at the FACP
Certifications:
- UL Standard 864
- ISO 9001
RZA-5F Remote Annunciator
RZA-5F remote annunciators support Fire-Light® fire alarm control panels (FACPs). They mount on a standard single-gang box and provide LED indication for five zones.
RZA-5F remote annunciators support Fire-Light® fire alarm control panels (FACPs). They mount on a standard single-gang box and provide LED indication for five zones. A local trouble sounder silence switch is also provided. All LED wiring is supervised. Any trouble condition will cause the system trouble LED to illuminate. These annunciators require the use of an LED interface module to communicate zone trouble conditions from the FACP back to the annunciator. The wiring is supervised for open conditions by these interface modules.

Features & Benefits:
Certifications:
- UL Listed: S2424
- CSFM 7120-0075:171
Certifications:
- UL Listed: S2424
- CSFM 7120-0075:171
SK-5235 Remote Annunciator
SK-5235 remote annunciators support Silent Knight® SK-5208 fire alarm control panels (FACPs).
SK-5235 remote annunciators support Silent Knight® SK-5208 fire alarm control panels (FACPs). These annunciators perform all system operations, provide trouble and alarm information, and can be used for programming.

Features & Benefits:
- 2 x 16 character LCD display
- Up to 6 per SK-5208 fire alarm control panel
- Each SK-5235 is individually supervised by the SK-5208
- Can be wired up to 1,500 ft from fire alarm control panel
- Operator’s key ships with SK-5235 and can be used to perform user operations but will not open the control panel door
Certifications:
- UL Listed
- MEA 429-92-E
- CSFM 7165-0559:137
SK-RZA4 Remote LED Annunciator
SK-RZA4 remote LED annunciators support Silent Knight® SK-4 fire alarm control panels (FACPs).
SK-RZA4 remote LED annunciators support Silent Knight® SK-4 fire alarm control panels (FACPs). These annunciators mount on a standard single-gang electrical box and provide LED indications for alarm zone 1 (red LED), alarm zone 2 (red LED), alarm zone 3 (red LED), alarm zone 4 (red LED), and system trouble (yellow).

Features & Benefits:
- Four Style B (Class B) initiating device circuits (IDCs)
- Two Style Y (Class B) notification appliance circuit (NAC)
- Optional module converts all IDCs and NACs to Class A (PN SK-CAC4)
- Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72
- Selectable for System Sensor, Wheelock, and Gentex protocols
- Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC
- Program for combination tamper supervisory monitor and waterflow alarm on one zone
- Silent or audible walk test operation mode
- Alarm verification selectable per zone
- Program each zone for supervisory or fire with separate red and yellow LEDs
- Disable switches provided per zone
- Program NACS for – Silence inhibit, auto-silence, strobe synchronization, temporal or steady signal Silenceable or non-silenceable – Disable, Form C alarm, trouble, and supervisory relays
- 3A total usable current
- 6A total usable current with optional, second transformer (PN SK-TRM24 or SK-TRM24E)
- Optional dress panel (PN SK-DP2/4)
Keeping You Informed
Alarmco Systems works with customers to keep them informed with new product solutions.
Process steps in our projects
Technology
Offer the best available products.
Design
System designs that are cost effective.
Development
Putting solutions in your business
Deployment
Monitoring 24/7/365